Francis Turbine Trainer
• A centrifugal pump and a flow control valve for adjusting the inlet pressure.
• The transparent operating area of the turbine enables an optimal view of water flow, rotor and guide vanes during operation.
• By adjusting the guide vanes the angle of attack, the cross-section and thus the output of the turbine are changed. An asynchronous machine is used as a • The generator is equipped with a pendulum bearing and with a force sensor to determine the torque.
• A pump with variable speed via frequency converter provides for an energy efficient operation.
• The measured values are displayed digitally and can be processed further on a PC.
• The speed of the turbine is recorded by means of an inductive, non-contact position sensor at the generator shaft.
• The pressures at the inlet and outlet of the turbine, the temperature and the flow rate are recorded by sensors.
• Hydraulic power: 2,1kW at 1500min-1
• Mechanical power: approx. 1,4kW at 1500min-1
• Rotor, D: 165mm
• 8 blades, 8 guide vanes
• Angle of attack adjustable: 0…23°
• Centrifugal pump, multistage.
• Pump head: 42m
• Tank: 550L
• Power consumption: 5,5kW
• Max. Flow rate: 900L/min
• Asynchronous machine as generator
• Output: 2,2kW at 1440min-1
• Temperature: 0…100°C
• Pressure (inlet): ±1bar (turbine)
• Pressure (outlet): 0…6bar (turbine)
• Flow rate: 0…1000L/min
• Torque: 0…20Nm
• Speed: 0…3000min-1
• 0…2200W (generator)
• 400V, 50Hz, 3 phases
• 400V, 60Hz, 3 phases, 230V, 60Hz, 3 phases
Dimension: 2350x1050x2050mm
Weight: approx. 580kg
Francis Turbine Trainer ALTEC Laboratory Equipments and ALTEC Laboratory Instruments Tenders.