Industrial Process Plant Trainer
Industrial Process Plant Trainer
Water from the Filtered water vessel is pumped forward through the
Cation vessel; this then enters the degasser vessel after experiencing a
carbonate removal process. Within the Acid Dosing vessel is a 5%
dilution of Hydrochloric Acid, which is used to regenerate the Cation
Bed. The degassed liquid is then pumped forward through the Anion Bed.
The Cation Bed and Anion Bed require a regenerating every 5 hours to
maintain the optimum condition of the resins. In the caustic dosing
vessel is a 4% dilution of Sodium Hydroxide; this is used to regenerate
the Anion Bed.
The Raw Water Filtration module houses the Raw Water vessel, two
independent sand filters and Filtered Water vessel. Mains water is
transferred into the raw water vessel, which is then pump forward
through either one of the sand filters into the filtered water vessel.
On the Dosing module there is a an acid dosing vessel, caustic dosing
vessel, Cation Bed, Anion Bed and Degasser vessel.
Industrial Process Plant Trainer ALTEC Laboratory Equipments and ALTEC Laboratory Instruments Tenders.